国产在线精品99一区,亚洲欧美日韩一级特黄在线,99视频精品国在线视频艾草,欧美人妻中文字幕天天弄

供應(yīng)WATSNA-250/4PCB級(jí)R/NSX-F80A雙電源_桔子電器_2022全

供應(yīng)WATSNA-250/4PCB級(jí)R/NSX-F80A雙電源_桔子電器_2022全

  • 類(lèi)別:
  • 價(jià)格:面議
  • 點(diǎn)擊率:0


WATSNA-250/4PCB級(jí)R/NSX-F40A
WATSNA-250/4PCB級(jí)R/NSX-F50A
WATSNA-250/4PCB級(jí)R/NSX-F63A
WATSNA-250/4PCB級(jí)R/NSX-F80A
WATSNA-250/4PCB級(jí)R/NSX-F100A
WATSNA-250/4PCB級(jí)R/NSX-F125A
WATSNA-250/4PCB級(jí)R/NSX-F160A
WATSNA-250/4PCB級(jí)R/NSX-F200A
WATSNA-250/4PCB級(jí)R/NSX-F250A
WATSNA-100/3PCB級(jí)R/NSX-N100A
WATSNA-100/3PCB級(jí)R/NSX-N16A
WATSNA-100/3PCB級(jí)R/NSX-N25A
WATSNA-100/3PCB級(jí)R/NSX-N32A
WATSNA-100/3PCB級(jí)R/NSX-N40A
WATSNA-100/3PCB級(jí)R/NSX-N50A
WATSNA-100/3PCB級(jí)R/NSX-N63A
WATSNA-100/3PCB級(jí)R/NSX-N80A
WATSNA-100/3PCB級(jí)R/NSX-N100A
WATSNA-100/4PCB級(jí)R/NSX-N16A
WATSNA-100/4PCB級(jí)R/NSX-N25A
WATSNA-100/4PCB級(jí)R/NSX-N32A
WATSNA-100/4PCB級(jí)R/NSX-N40A
WATSNA-100/4PCB級(jí)R/NSX-N50A
WATSNA-100/4PCB級(jí)R/NSX-N63A
WATSNA-100/4PCB級(jí)R/NSX-N80A
WATSNA-100/4PCB級(jí)R/NSX-N100A
WATSNA-100/4PCB級(jí)R/NSX-N16A
WATSNA-100/4PCB級(jí)R/NSX-N25A
WATSNA-100/4PCB級(jí)R/NSX-N32A
WATSNA-100/4PCB級(jí)R/NSX-N40A
WATSNA-100/4PCB級(jí)R/NSX-N50A
WATSNA-100/4PCB級(jí)R/NSX-N63A
WATSNA-100/4PCB級(jí)R/NSX-N80A
WATSNA-100/4PCB級(jí)R/NSX-N100A
WATSNA-160/3PCB級(jí)R/NSX-N50A
WATSNA-160/3PCB級(jí)R/NSX-N63A
WATSNA-160/3PCB級(jí)R/NSX-N80A
WATSNA-160/3PCB級(jí)R/NSX-N100A
WATSNA-160/3PCB級(jí)R/NSX-N125A
WATSNA-160/3PCB級(jí)R/NSX-N160A
WATSNA-160/4PCB級(jí)R/NSX-N40A
WATSNA-160/4PCB級(jí)R/NSX-N50A
WATSNA-160/4PCB級(jí)R/NSX-N63A
WATSNA-160/4PCB級(jí)R/NSX-N80A
WATSNA-160/4PCB級(jí)R/NSX-N100A
WATSNA-160/4PCB級(jí)R/NSX-N125A
WATSNA-160/4PCB級(jí)R/NSX-N160A
WATSNA-250/4PCB級(jí)R/NSX-N40A
WATSNA-250/4PCB級(jí)R/NSX-N50A
WATSNA-250/4PCB級(jí)R/NSX-N63A
WATSNA-250/4PCB級(jí)R/NSX-N80A
WATSNA-250/4PCB級(jí)R/NSX-N100A
WATSNA-250/4PCB級(jí)R/NSX-N125A
WATSNA-250/4PCB級(jí)R/NSX-N160A
WATSNA-250/4PCB級(jí)R/NSX-N200A
WATSNA-250/4PCB級(jí)R/NSX-N250A
WATSNA-100/3PCB級(jí)R/NSX-H100A
WATSNA-100/3PCB級(jí)R/NSX-H16A
WATSNA-100/3PCB級(jí)R/NSX-H25A
WATSNA-100/3PCB級(jí)R/NSX-H32A
WATSNA-100/3PCB級(jí)R/NSX-H40A
WATSNA-100/3PCB級(jí)R/NSX-H50A
WATSNA-100/3PCB級(jí)R/NSX-H63A
WATSNA-100/3PCB級(jí)R/NSX-H80A
WATSNA-100/3PCB級(jí)R/NSX-H100A
WATSNA-100/4PCB級(jí)R/NSX-H16A
WATSNA-100/4PCB級(jí)R/NSX-H25A
WATSNA-100/4PCB級(jí)R/NSX-H32A
WATSNA-100/4PCB級(jí)R/NSX-H40A
WATSNA-100/4PCB級(jí)R/NSX-H50A
WATSNA-100/4PCB級(jí)R/NSX-H63A
WATSNA-100/4PCB級(jí)R/NSX-H80A
WATSNA-100/4PCB級(jí)R/NSX-H100A
WATSNA-100/4PCB級(jí)R/NSX-H16A
WATSNA-100/4PCB級(jí)R/NSX-H25A
WATSNA-100/4PCB級(jí)R/NSX-H32A
WATSNA-100/4PCB級(jí)R/NSX-H40A
WATSNA-100/4PCB級(jí)R/NSX-H50A
WATSNA-100/4PCB級(jí)R/NSX-H63A
WATSNA-100/4PCB級(jí)R/NSX-H80A
WATSNA-100/4PCB級(jí)R/NSX-H100A
WATSNA-160/3PCB級(jí)R/NSX-H50A
WATSNA-160/3PCB級(jí)R/NSX-H63A
WATSNA-160/3PCB級(jí)R/NSX-H80A
WATSNA-160/3PCB級(jí)R/NSX-H100A
WATSNA-160/3PCB級(jí)R/NSX-H125A
WATSNA-160/3PCB級(jí)R/NSX-H160A
WATSNA-160/4PCB級(jí)R/NSX-H40A
WATSNA-160/4PCB級(jí)R/NSX-H50A
WATSNA-160/4PCB級(jí)R/NSX-H63A
WATSNA-160/4PCB級(jí)R/NSX-H80A
WATSNA-160/4PCB級(jí)R/NSX-H100A
WATSNA-160/4PCB級(jí)R/NSX-H125A
WATSNA-160/4PCB級(jí)R/NSX-H160A
WATSNA-250/4PCB級(jí)R/NSX-H40A
WATSNA-250/4PCB級(jí)R/NSX-H50A
WATSNA-250/4PCB級(jí)R/NSX-H63A
WATSNA-250/4PCB級(jí)R/NSX-H80A
WATSNA-250/4PCB級(jí)R/NSX-H100A
WATSNA-250/4PCB級(jí)R/NSX-H125A
WATSNA-250/4PCB級(jí)R/NSX-H160A
WATSNA-250/4PCB級(jí)R/NSX-H200A
WATSNA-250/4PCB級(jí)R/NSX-H250A





三、如何調(diào)試雙電源自動(dòng)轉(zhuǎn)換開(kāi)關(guān)
首先將雙電源放置調(diào)整臺(tái)上,相線(xiàn)與中性線(xiàn)(零線(xiàn))按位對(duì)接,不能接錯(cuò)。
三極開(kāi)關(guān)接線(xiàn)時(shí),常用與備用零線(xiàn)需接至零線(xiàn)端子(NN與RN)位置上。
線(xiàn)接完后,需要在次對(duì)安裝的線(xiàn)路進(jìn)行檢查,然后打開(kāi)調(diào)試臺(tái)總開(kāi)關(guān),開(kāi)啟常用及備用工作電源。
當(dāng)雙電源轉(zhuǎn)換開(kāi)關(guān)在自投自復(fù)模式,兩路工作電源正常的情況下,開(kāi)關(guān)應(yīng)自動(dòng)轉(zhuǎn)換至常用電源位。
設(shè)置常用電源NA、NB、NC、NN任意相斷相,雙電源應(yīng)轉(zhuǎn)換至備用電源,如常用電源恢復(fù)正常,應(yīng)重新轉(zhuǎn)換至常用電源。調(diào)節(jié)常用電源任意一相至規(guī)定電壓值以下(即欠壓狀態(tài)),雙電源應(yīng)轉(zhuǎn)換至備用電源。當(dāng)常用電源恢復(fù)正常,應(yīng)重新轉(zhuǎn)換至常用電源。
如備用電源任意相斷相,報(bào)警器應(yīng)散發(fā)報(bào)警聲。
常用電源和備用電源任意相斷開(kāi),控制器上對(duì)應(yīng)顯示數(shù)值應(yīng)對(duì)應(yīng)消失。
當(dāng)設(shè)置雙電源為手動(dòng)操作模式時(shí),通過(guò)控制器手動(dòng)操作按鍵,需自由在常用電源及備用電源間轉(zhuǎn)換,顯示屏顯示準(zhǔn)確。
操作控制器上的雙分按鍵。雙電源需應(yīng)同時(shí)候分?jǐn)喑S眉皞溆秒娫矗虻诫p分位置。
調(diào)節(jié)萬(wàn)用表至電壓AC750V檔位,分別檢測(cè)常用電源及備用電源指示燈輸出端子電壓值。



斷路器
斷路器是指能夠關(guān)合、承載和開(kāi)斷正?;芈窏l件下的電流并能在規(guī)定的時(shí)間內(nèi)關(guān)合、承載和開(kāi)斷異常回路條件下的電流的開(kāi)關(guān)裝置。斷路器按其使用范圍分為高壓斷路器與低壓斷路器,高低壓界線(xiàn)劃分比較模糊,一般將3kV以上的稱(chēng)為高壓電器。 斷路器可用來(lái)分配電能,不頻繁地啟動(dòng)異步電動(dòng)機(jī),對(duì)電源線(xiàn)路及電動(dòng)機(jī)等實(shí)行保護(hù),當(dāng)它們發(fā)生嚴(yán)重的過(guò)載或者短路及欠壓等故障時(shí)能自動(dòng)切斷電路,其功能相當(dāng)于熔斷器式開(kāi)關(guān)與過(guò)欠熱繼電器等的組合。而且在分?jǐn)喙收想娏骱笠话悴恍枰兏悴考D壳?,已獲得了廣泛的應(yīng)用。 電的產(chǎn)生、輸送、使用中,配電是一個(gè)極其重要的環(huán)節(jié)。配電系統(tǒng)包括變壓器和各種高低壓電器設(shè)備,低壓斷路器則是一種使用量大面廣的電器。


绥德县| 特克斯县| 东城区| 滁州市| 封开县| 临汾市| 微山县| 富锦市| 都江堰市| 明溪县| 拉萨市| 申扎县| 贡嘎县| 屏东县| 房山区| 玛沁县| 香格里拉县| 巴南区| 隆安县| 岳池县| 五华县| 瑞安市| 灌南县| 南开区| 来宾市| 偏关县| 马尔康县| 泉州市| 黄梅县| 冀州市| 华容县| 石棉县| 错那县| 清镇市| 海口市| 渭南市| 巩留县| 合阳县| 灵宝市| 新余市| 南和县|